PSC LINEAR IMAGER 7000 Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Leitores de códigos de barras PSC LINEAR IMAGER 7000. PSC LINEAR IMAGER 7000 Programming instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 212
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Linear Imager

PowerScan® 7000Linear ImagerProduct Reference Guide

Página 2

Getting Started1-4 PowerScan® 7000 Linear ImagerWand Emulation Connection — Connect the scanner to the appro-priated port on the terminal/PC using the

Página 3 - Table of Contents

Symbologies5-8 PowerScan® 7000 Linear ImagerUPC-EThe following options apply to the UPC-E symbology.Disable/Enable UPC-EWhen disabled, the scanner wil

Página 4

UPC-EProduct Reference Guide 5-9UPC-E — continuedSTARTSTATE BARCODEDisable UPC-EEnable UPC-EDon’t Send Check DigitSendCheck DigitExclude Sys-tem Numbe

Página 5 - Product Reference Guide iii

Symbologies5-10 PowerScan® 7000 Linear ImagerDon’t Expand UPC-E toUPC-AExpand UPC-E to UPC-ADon’t Expand UPC-E toEAN-13Expand UPC-E to EAN-13ENDUPC-E

Página 6

UPC-EProduct Reference Guide 5-11UPC-E — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a UPC-E label must be de

Página 7 - Getting Started

Symbologies5-12 PowerScan® 7000 Linear ImagerGTINThe following options apply to the GTIN label data format.Disable/Enable GTINWhen this feature is ena

Página 8 - Connecting the Scanner

EAN-13Product Reference Guide 5-13EAN-13The following options apply to the EAN-13 symbology.Disable/Enable EAN-13When disabled, the scanner will not r

Página 9 - Reference

Symbologies5-14 PowerScan® 7000 Linear ImagerEAN-13 — continuedSTARTSTATE BARCODEDisable EAN-13Enable EAN-13Don’t Send Check DigitSendCheck DigitDon’t

Página 10 - Defaults

EAN-13Product Reference Guide 5-15Disable ISBNEnable ISBNENDEAN-13 — continuedSTARTSTATE BARCODE

Página 11 - General Features

Symbologies5-16 PowerScan® 7000 Linear ImagerEAN-13 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an EAN-13 l

Página 12 - 2-2 PowerScan

EAN-8Product Reference Guide 5-17EAN-8The following options apply to the EAN-8 symbology.Disable/Enable EAN-8When disabled, the scanner will not read

Página 13 - Powerdown Timeout

Product Reference Guide 2-1Chapter 2General FeaturesDouble Read TimeoutThe Double Read Timeout feature sets a time limit that determines how much time

Página 14 - Powerdown Timeout — continued

Symbologies5-18 PowerScan® 7000 Linear ImagerEAN-8 — continuedExpand EAN-8 to EAN-13 — Expands EAN-8 data to the EAN-13 data format. Selecting this fe

Página 15 - LED and Beeper Indicators

EAN-8Product Reference Guide 5-19EAN-8 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an EAN-8 label must be d

Página 16 - Good Read: When to Indicate

Symbologies5-20 PowerScan® 7000 Linear ImagerAdd-onsAdd-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scann

Página 17 - Good Read Beep Control

Add-onsProduct Reference Guide 5-21Add-ons — continuedSTARTSTATE BARCODEDisable Optional 2-Digit Add-onsEnable Optional 2-Digit Add-onsDisable Optiona

Página 18 - Good Read Beep Frequency

Symbologies5-22 PowerScan® 7000 Linear ImagerRSS-14The following options apply to the RSS-14 symbology.Disable/Enable RSS-14When this feature is disab

Página 19 - Good Read Beep Length

RSS-14Product Reference Guide 5-23RSS-14 — continuedSTARTSTATE BARCODEDisableRSS-14Enable RSS-14DisableUCC/EAN 128 EmulationEnableUCC/EAN 128 Emulatio

Página 20 - 2-10 PowerScan

Symbologies5-24 PowerScan® 7000 Linear ImagerRSS-14 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS-14 l

Página 21 - Good Read Beep Volume

RSS ExpandedProduct Reference Guide 5-25RSS ExpandedThe following options apply to the RSS Expanded symbology.Disable/Enable RSS ExpandedWhen this fea

Página 22 - Scanning Features

Symbologies5-26 PowerScan® 7000 Linear ImagerRSS Expanded — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the

Página 23 - Scan Mode — continued

RSS ExpandedProduct Reference Guide 5-27RSS Expanded — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 24 - Active Scanning Time

General Features2-2 PowerScan® 7000 Linear ImagerDouble Read Timeout — continuedSTARTDURATION BARCODE0.5 Second0.6 Second0.7 Second0.8 Second0.9 Secon

Página 25

Symbologies5-28 PowerScan® 7000 Linear ImagerRSS Expanded — continuedRSS Expanded Length 1, Length 2 Pro-gramming Instructions1. Scan the START bar co

Página 26 - Laser Pointer Control

RSS ExpandedProduct Reference Guide 5-29RSS Expanded — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS Exp

Página 27

Symbologies5-30 PowerScan® 7000 Linear ImagerCode 39The following options apply to the Code 39 symbology.Disable/Enable Code 39When this feature is di

Página 28 - 2-18 PowerScan

Code 39Product Reference Guide 5-31Code 39 — continuedSTARTSTATE BARCODEDisableCode 39EnableCode 39DisableCheck CharCalculationEnableCheck CharCalcula

Página 29 - Features

Symbologies5-32 PowerScan® 7000 Linear ImagerCode 39 — continuedSTARTSTATE BARCODEDon’t TransmitStart/Stop CharactersTransmitStart/Stop CharactersDisa

Página 30

Code 39Product Reference Guide 5-33Code 39 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Página 31

Symbologies5-34 PowerScan® 7000 Linear ImagerCode 39 — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 32 - Interface Selection

Code 39Product Reference Guide 5-35Code 39 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either the Set Length 1 or Se

Página 33 - Interface Selection — cont

Symbologies5-36 PowerScan® 7000 Linear ImagerCode 39 — continuedQuiet ZonesThis feature enables/disables the requirement that quiet zones must be pres

Página 34

Code 39Product Reference Guide 5-37Code 39 — continuedCode 39 StitchingEnables/disables stitching for Code 39 labels. When parts of a Code 39 bar code

Página 35

Powerdown TimeoutProduct Reference Guide 2-3Powerdown TimeoutThe Powerdown Timeout feature sets the time for automatically switching the unit off when

Página 36 - Interface Features

Symbologies5-38 PowerScan® 7000 Linear ImagerCode 39 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 39

Página 37 - Global Interface Features

Pharmacode 39Product Reference Guide 5-39Pharmacode 39The following options apply to the Pharmacode 39 symbology.Disable/Enable Pharmacode 39When this

Página 38 - RS-232 Interface Features

Symbologies5-40 PowerScan® 7000 Linear ImagerPharmacode 39 — continuedStart/Stop CharactersEnables or disables transmission of Pharmacode 39 start/sto

Página 39

Code 128Product Reference Guide 5-41Code 128The following options apply to the Code 128 symbology.Disable/Enable Code 128When this feature is disabled

Página 40 - 3-12 PowerScan

Symbologies5-42 PowerScan® 7000 Linear ImagerCode 128 — continuedTransmit Function CharactersEnables/disables transmission of Code128 function charact

Página 41

Code 128Product Reference Guide 5-43Code 128 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will

Página 42 - Software Flow Control

Symbologies5-44 PowerScan® 7000 Linear ImagerCode 128 — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 43

Code 128Product Reference Guide 5-45Code 128 — continuedCode 128 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either

Página 44 - 3-16 PowerScan

Symbologies5-46 PowerScan® 7000 Linear ImagerCode 128 — continuedCode 128 StitchingEnables/disables stitching for Code 128 labels. When parts of a Cod

Página 45

Code 128Product Reference Guide 5-47Code 128 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 128 label

Página 46 - RS-232 Invert

General Features2-4 PowerScan® 7000 Linear ImagerPowerdown Timeout — continuedSTARTDURATION BARCODE3 Minutes4 MinutesEND

Página 47

Symbologies5-48 PowerScan® 7000 Linear ImagerInterleaved 2 of 5The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbol-ogy.Disable/Ena

Página 48 - 3-20 PowerScan

Interleaved 2 of 5Product Reference Guide 5-49Interleaved 2 of 5 — continuedSTARTSTATE BARCODEDisableInterleaved2 of 5EnableInterleaved2 of 5DisableCh

Página 49 - Beep on Not on File

Symbologies5-50 PowerScan® 7000 Linear ImagerInterleaved 2 of 5 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled

Página 50 - ACK NAK Options

Interleaved 2 of 5Product Reference Guide 5-51Interleaved 2 of 5 — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 51 - ACK NAK Options — cont

Symbologies5-52 PowerScan® 7000 Linear ImagerInterleaved 2 of 5 — continuedInterleaved 2 of 5 Length 1, Length 2 Pro-gramming Instructions1. Scan the

Página 52 - ACK Character

Interleaved 2 of 5Product Reference Guide 5-53Interleaved 2 of 5 StitchingEnables/disables stitching for Interleaved 2 of 5 labels. When parts of an I

Página 53 - NAK Character

Symbologies5-54 PowerScan® 7000 Linear ImagerInterleaved 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times

Página 54 - Retry on ACK NAK Timeout

CodabarProduct Reference Guide 5-55CodabarThe following options apply to the Codabar symbology.Disable/Enable CodabarWhen this feature is disabled, th

Página 55 - ACK NAK Timeout Value

Symbologies5-56 PowerScan® 7000 Linear ImagerCodabar — continuedSTARTSTATE BARCODEDisableCodabarEnableCodabarDisableCheck CharVerificationEnableCheck

Página 56 - ACK NAK Retry Count

CodabarProduct Reference Guide 5-57Codabar — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Página 57 - ACK NAK Error Handling

LED and Beeper IndicatorsProduct Reference Guide 2-5LED and Beeper IndicatorsPower On AlertDisables or enables the indication (from the Beeper) that t

Página 58 - 3-30 PowerScan

Symbologies5-58 PowerScan® 7000 Linear ImagerCodabar — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 59 - IBM-USB Interface Features

CodabarProduct Reference Guide 5-59Codabar — continuedCodabar Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either the

Página 60 - 3-32 PowerScan

Symbologies5-60 PowerScan® 7000 Linear ImagerCodabar — continuedQuiet ZonesThis feature enable/disables the requirement that quiet zones must be prese

Página 61

CodabarProduct Reference Guide 5-61Codabar — continuedStart/Stop Character TypeCodabar has four pairs of Start/Stop patterns. Select one pair to match

Página 62 - Wand Emulation — cont

Symbologies5-62 PowerScan® 7000 Linear ImagerCodabar — continuedSTARTSTATE BARCODEStart/Stop Type: ABCD/TN*EStart/Stop Type: ABCD/ABCDStart/Stop Type:

Página 63

CodabarProduct Reference Guide 5-63Codabar — continuedSTARTSTATE BARCODEDisable Start/Stop Char MatchEnable Start/Stop Char MatchEND

Página 64

Symbologies5-64 PowerScan® 7000 Linear ImagerCodabar — continuedCodabar StitchingEnables/disables stitching for Codabar labels. When parts of a Codaba

Página 65

Codabar — continuedProduct Reference Guide 5-65Codabar — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Codab

Página 66 - Symbology Conversion

Symbologies5-66 PowerScan® 7000 Linear ImagerCode 93The following options apply to the Code 93 symbology.Disable/Enable Code 93When this feature is di

Página 67 - Symbology Conversion — cont

Code 93Product Reference Guide 5-67Code 93 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Página 68 - Keyboard Wedge/USB Keyboard

General Features2-6 PowerScan® 7000 Linear ImagerGood Read: When to IndicateThis feature specifies when the scanner will provide indication (beep and/

Página 69

Symbologies5-68 PowerScan® 7000 Linear ImagerCode 93 — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 70 - 3-42 PowerScan

Code 93Product Reference Guide 5-69Code 93 — continuedCode 93 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either the

Página 71

Symbologies5-70 PowerScan® 7000 Linear ImagerCode 93 — continuedCode 93 StitchingEnables/disables stitching for Code 93 bar codes. When parts of a Cod

Página 72 - 3-44 PowerScan

Code 93Product Reference Guide 5-71Code 93 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 93 label mus

Página 73

Symbologies5-72 PowerScan® 7000 Linear ImagerMSI/PlesseyThe following options apply to the MSI/Plessey symbology.Disable/Enable MSI/PlesseyWhen this f

Página 74 - 3-46 PowerScan

MSI/PlesseyProduct Reference Guide 5-73MSI/Plessey — continuedSTARTSTATE BARCODEDisableMSI/PlesseyEnableMSI/PlesseyDisableCheck DigitVerificationEnabl

Página 75 - Set Wedge Quiet Interval

Symbologies5-74 PowerScan® 7000 Linear ImagerDisableCheck DigitTransmissionEnableCheck DigitTransmissionENDMSI/Plessey — continuedSTARTSTATE BARCODE

Página 76 - Numeric Pad

MSI/PlesseyProduct Reference Guide 5-75MSI/Plessey — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner

Página 77 - Data Editing

Symbologies5-76 PowerScan® 7000 Linear ImagerMSI/Plessey — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 78 - Global Prefix/Suffix

MSI/PlesseyProduct Reference Guide 5-77MSI/Plessey — continuedMSI/Plessey Length 1, Length 2 Program-ming Instructions1. Scan the START bar code.2. Sc

Página 79 - Appendix C

LED and Beeper IndicatorsProduct Reference Guide 2-7Good Read Beep ControlThis feature enables/disables the scanner’s ability to beep upon a success-f

Página 80 - Appendix C, Alpha-Numeric

Symbologies5-78 PowerScan® 7000 Linear ImagerMSI/Plessey — continuedMSI/Plessey StitchingEnables/disables stitching for MSI/Plessey bar codes. When pa

Página 81

MSI/PlesseyProduct Reference Guide 5-79MSI/Plessey — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an MSI/Pless

Página 82 - AIM ID — continued

Symbologies5-80 PowerScan® 7000 Linear ImagerStandard 2 of 5The following options apply to the Standard 2 of 5 symbology.Disable/Enable Standard 2 of

Página 83 - Label ID

Standard 2 of 5Product Reference Guide 5-81Standard 2 of 5 — continuedSTARTSTATE BARCODEDisableStd 2 of 5EnableStd 2 of 5DisableCheck DigitVerificatio

Página 84 - Label ID — continued

Symbologies5-82 PowerScan® 7000 Linear ImagerStandard 2 of 5 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, t

Página 85

Standard 2 of 5Product Reference Guide 5-83Standard 2 of 5 — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 86

Symbologies5-84 PowerScan® 7000 Linear ImagerStandard 2 of 5 — continuedStandard 2 of 5 Length 1, Length 2 Pro-gramming Instructions1. Scan the START

Página 87

Standard 2 of 5Product Reference Guide 5-85Standard 2 of 5 — continuedStandard 2 of 5 StitchingEnables/disables stitching for Standard 2 of 5 bar code

Página 88

Symbologies5-86 PowerScan® 7000 Linear ImagerStandard 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a

Página 89

PDF 417Product Reference Guide 5-87PDF 417The following options apply to the PDF 417 symbology.Disable/Enable PDF 417When this feature is disabled, th

Página 90 - Case Conversion

General Features2-8 PowerScan® 7000 Linear ImagerGood Read Beep FrequencyAdjusts the good read beep to sound at a selectable low, medium or high frequ

Página 91 - Character Conversion

Symbologies5-88 PowerScan® 7000 Linear ImagerPDF 417 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scann

Página 92 - 4-16 PowerScan

PDF 417Product Reference Guide 5-89PDF 417 — continuedSTARTMODE BARCODEVariable LengthDecodingFixed Length DecodingEND

Página 93

Symbologies5-90 PowerScan® 7000 Linear ImagerPDF 417 — continuedPDF 417 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan

Página 94 - System Number Transmission

PDF 417Product Reference Guide 5-91PDF 417 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a PDF 417 label must

Página 95 - UPC-A — continued

Symbologies5-92 PowerScan® 7000 Linear ImagerNOTES

Página 96

Product Reference Guide A-1Appendix AProduct SpecificationsOptical and Read Performance ParametersParameter SpecificationScanning Width2” wide at 1”

Página 97

A-2 PowerScan® 7000 Linear ImagerPhysical PropertiesElectrical ParametersParameter SpecificationDimensions (Typical):Height 7.5”/190 mmLength 4.5”/11

Página 98

Environmental ParametersProduct Reference Guide A-3Environmental ParametersOther ParametersParameter SpecificationMechanical Shock50 drops from 6.5 fe

Página 99

A-4 PowerScan® 7000 Linear ImagerNOTES

Página 100 - Expand UPC-E to EAN13

Product Reference Guide B-1Appendix BCable PinoutsStandard Cable Pinouts (Primary Interface Cables)RS-232IBM Port 5B/9B/1712CTS34RTS5 RXD6TXD78VCC IN

Página 101 - UPC-E — continued

LED and Beeper IndicatorsProduct Reference Guide 2-9Good Read Beep LengthSpecifies the duration of a good read beep.STARTLENGTH BARCODE60msec80msec100

Página 102

Cable PinoutsB-2 PowerScan® 7000 Linear ImagerIBM USBUSB & USB KeyboardWand Emulation1234D -56D +78VIN9GND101234D -56D +78 VBUS_VIN9GND10123 WAND~

Página 103

Standard Cable Pinouts (Primary Interface Cables)Product Reference Guide B-3Keyboard Wedge12 KB_DATA3 AT_CLK4 KB_CLK56 AT_DATA78VCC_IN9GND10Pin 110 Po

Página 104 - Disable/Enable GTIN

Cable PinoutsB-4 PowerScan® 7000 Linear ImagerNOTES

Página 105 - EAN-13 Flag 1 Character

Product Reference Guide C-1Appendix CAlpha-Numeric PadABCDEF

Página 106 - EAN-13 — continued

C-2 PowerScan® 7000 Linear ImagerAlpha-Numeric Pad1230987654

Página 107

Product Reference Guide D-1Appendix DDefault SettingsDefaults by SymbologyThe following is a partial list of key settings for each symbology type.Code

Página 108

D-2 PowerScan® 7000 Linear ImagerInterface Default ExceptionsThe factory default settings indicated in the programming sections (by bold text and yell

Página 109 - Disable/Enable EAN-8

Interface Default ExceptionsProduct Reference Guide D-3RS-232 Wincor/NixdorfParameter Default SettingInterface Type RS-232-WNNumber of Host Transmit B

Página 110 - EAN-8 — continued

D-4 PowerScan® 7000 Linear ImagerKeyboardsKeyboard interfaces include USB Keyboard and Keyboard Wedge A-Y.Parameter Default SettingKeyboard Wedge Inte

Página 111

Product Reference Guide E-1Appendix EKeyboard FunctionKey MappingsKeyboard Model Cross ReferenceTa bl e E - 2 summarizes the keyboard models, their

Página 112 - 7000 Linear Imager

PSC Inc959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No part of the cont

Página 113 - Add-ons — continued

General Features2-10 PowerScan® 7000 Linear ImagerGood Read Beep Length — continuedSTARTLENGTH BARCODE180msec200msecEND

Página 114 - UCC/EAN 128 Emulation

E-2 PowerScan® 7000 Linear ImagerTable E-1. Keyboard Model Cross ReferenceModel Type I/F IDTrans-mission ProtocolScancodeSetFunc.KeyMap SupportUseCoun

Página 115 - RSS-14 — continued

Keyboard Model Cross ReferenceProduct Reference Guide E-3Table E-2. Scanset 1 Function Key MapASCII (hex)ASCII code Key Scancode00 NUL ALT right Mak

Página 116

E-4 PowerScan® 7000 Linear ImagerTable E-3. Scanset 2 Function Key MapASCII (hex)ASCII code Key Scancode00 NUL ALT right Make E0h 11h01 SOH ALT rig

Página 117 - RSS Expanded

Keyboard Model Cross ReferenceProduct Reference Guide E-5Table E-4. Scanset 3, 102-Key Function Key MapASCII (hex) ASCII code Key Scancode00 NUL ALT r

Página 118 - RSS Expanded — continued

E-6 PowerScan® 7000 Linear ImagerTable E-5. Scanset 3 122-Key Function Key MapASCII (hex) ASCII code Key Scancode00 NUL ALT Right Make 39h01 SOH ALT

Página 119

Keyboard Model Cross ReferenceProduct Reference Guide E-7Table E-6. Japanese DOS Function Key MapASCII value ASCII code Key Scancode00h NUL ALT right

Página 120

E-8 PowerScan® 7000 Linear ImagerTable E-7. NEC 9801-Key Function Key MapASCII value ASCII code Key Scancode00h NUL unused n/a01h SOH CR 1Ch02h STX C

Página 121

Product Reference Guide F-1Appendix FHost CommandsAccepting RS-232 CommandsThe scanner responds to the following RS-232 commands:If one of the above

Página 122 - Code 39 Full ASCII

F-2 PowerScan® 7000 Linear ImagerNOTES

Página 123 - Code 39 — continued

Product Reference Guide G-1Appendix GSample Symbols0 123456 78901234567890Code 1289 780330 290951BC321123456-9$123456UPC-ACode 128Code 39Code 93I

Página 124

LED and Beeper IndicatorsProduct Reference Guide 2-11Good Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three

Página 125

G-2 PowerScan® 7000 Linear ImagerSample Symbols(01)00123456789012Car RegistrationPDF417RSS-140100123456789050RSS Expanded

Página 126

ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE

Página 127 - Instructions

Asia PacificPSC Hong KongHong KongTelephone: [852]-2-584-6210Fax: [852]-2-521-0291AustraliaPSC Asia Pacific Pty Ltd.North Ryde, AustraliaTelephone: [

Página 128

General Features2-12 PowerScan® 7000 Linear ImagerScanning FeaturesScan ModeSelects the scan operating mode for the scanner. Selections are:• Single —

Página 129

Scanning FeaturesProduct Reference Guide 2-13Scan Mode — continuedSTARTMODE BARCODESingleTriggerlessStandStand w/IllumEND

Página 130

General Features2-14 PowerScan® 7000 Linear ImagerActive Scanning TimeThis setting determines the amount of time the scanner continues to scan in trig

Página 131 - Pharmacode 39

Scanning FeaturesProduct Reference Guide 2-15Active Scanning Time — continuedSTARTDURATION BARCODE2 Minutes3 Minutes4 MinutesEND

Página 132 - Pharmacode 39 — continued

General Features2-16 PowerScan® 7000 Linear ImagerLaser Pointer ControlWhen the trigger is pressed and Scan Mode is set to Single, the laser pointer w

Página 133 - Code 128

Scanning FeaturesProduct Reference Guide 2-17Laser Pointer Control — continuedSTARTDURATION BARCODE0.5 Seconds0.6 Seconds0.8 Seconds1 Second1.2 Second

Página 134 - Code 128 — continued

General Features2-18 PowerScan® 7000 Linear ImagerLaser Pointer Control — continuedSTARTDURATION BARCODE2 Seconds2.5 SecondsEND

Página 135

Product Reference Guide 3-1Chapter 3Interface RelatedFeaturesAt the time of this writing, the Scanner supports the interfaces listed in Tab le 3 - 1.

Página 136

Product Reference Guide iTable of ContentsAbout This Manual ... 1-1Manual Co

Página 137

Interface Related Features3-2 PowerScan® 7000 Linear ImagerTable 3-1. Interfaces SupportedRS-232 Page Keyboard Wedge PageRS-232 Standard3-10Keyboard W

Página 138

Product Reference Guide 3-3Table 3-2. Keyboard Wedge Interface ReferenceI/F Type PCs SupportedA PC/XT w/Alternate Key EncodingBAT, PS/2 25-286, 30-286

Página 139

Interface Related Features3-4 PowerScan® 7000 Linear ImagerInterface SelectionSTARTINTERFACE BARCODERS-232StandardRS-232Wincor-NixdorfIBM 4683Port 5BI

Página 140 - Interleaved 2 of 5

Interface SelectionProduct Reference Guide 3-5Interface Selection — cont.STARTINTERFACE BARCODEKeyboardWedge AKeyboardWedge BKeyboardWedge CKeyboardWe

Página 141

Interface Related Features3-6 PowerScan® 7000 Linear ImagerInterface Selection — cont.STARTINTERFACE BARCODEKeyboardWedge HKeyboardWedge IKeyboardWedg

Página 142 - Length Control

Interface SelectionProduct Reference Guide 3-7Interface Selection — cont.STARTINTERFACE BARCODEKeyboardWedge OKeyboardWedge PKeyboardWedge QKeyboardWe

Página 143

Interface Related Features3-8 PowerScan® 7000 Linear ImagerInterface Selection — cont.Interface FeaturesSTARTINTERFACE BARCODEKeyboardWedge UKeyboardW

Página 144 - 5-52 PowerScan

Interface FeaturesProduct Reference Guide 3-9Global Interface FeaturesSTARTSTATE BARCODEObey HostCommandsIgnore HostCommandsHostTransmissionBuffers =

Página 145 - Interleaved 2 of 5 Stitching

Interface Related Features3-10 PowerScan® 7000 Linear ImagerRS-232 Interface FeaturesSTARTBAUD RATE BARCODE1200 Baud2400 Baud4800 Baud9600 Baud19200 B

Página 146 - Minimum Reads

Interface FeaturesProduct Reference Guide 3-11RS-232 Interface Features — cont.STARTBAUD RATE BARCODE57600 Baud115200 BaudEND

Página 147 - Check Character Verification

ii PowerScan® 7000Wand Idle State ...3-34Signal Speed...

Página 148 - Codabar — continued

Interface Related Features3-12 PowerScan® 7000 Linear ImagerRS-232 Interface Features — cont.STARTSTATE BARCODE7 Data Bits8 Data Bits1 Stop Bit2 Stop

Página 149

Interface FeaturesProduct Reference Guide 3-13RS-232 Interface Features — cont.STARTSTATE BARCODEParity = EvenParity = OddEND

Página 150

Interface Related Features3-14 PowerScan® 7000 Linear ImagerRS-232 Interface Features — cont.Hardware Flow ControlDisable Hardware Control — The scann

Página 151

Interface FeaturesProduct Reference Guide 3-15RS-232 Interface Features — cont.STARTSTATE BARCODEDisableHardwareControlEnable CTS Flow ControlEnable C

Página 152

Interface Related Features3-16 PowerScan® 7000 Linear ImagerInterchar Delay = 30 msecInterchar Delay = 40 msecInterchar Delay = 50 msecInterchar Delay

Página 153

Interface FeaturesProduct Reference Guide 3-17Interchar Delay = 90 msecDisableSoftware Flow ControlEnableSoftware Flow ControlENDRS-232 Interface Feat

Página 154

Interface Related Features3-18 PowerScan® 7000 Linear ImagerRS-232 Interface Features — cont.Host EchoWhen enabled, this feature passes all data throu

Página 155

Interface FeaturesProduct Reference Guide 3-19RS-232 Interface Features — cont.STARTSTATE BARCODEDisable Host EchoEnable Host EchoHost Echo Quiet Inte

Página 156

Interface Related Features3-20 PowerScan® 7000 Linear ImagerHost Echo Quiet Interval= 40msecHost Echo Quiet Interval= 50msecHost Echo Quiet Interval=

Página 157

Interface FeaturesProduct Reference Guide 3-21Beep on ASCII BELEnables/disables ability of scanner to beep (sound a good read tone) on receiving an AS

Página 158 - Disable/Enable Code 93

Product Reference Guide iiiCode 39 ... 5-30Disable/Enable Code 3

Página 159 - Code 93 — continued

Interface Related Features3-22 PowerScan® 7000 Linear ImagerACK NAK OptionsThis enables/disables the ability of the scanner to support the RS-232 ACK/

Página 160

Interface FeaturesProduct Reference Guide 3-23ACK NAK Options — cont.STARTSTATE BARCODEDisable ACK NAKEnable ACK NAK forTransmissionEnable ACK NAK for

Página 161

Interface Related Features3-24 PowerScan® 7000 Linear ImagerRS-232 Interface Features — cont.ACK CharacterSTARTMODE BARCODESets the ACK character from

Página 162

Interface FeaturesProduct Reference Guide 3-25RS-232 Interface Features — cont.NAK CharacterSTARTMODE BARCODESets the NAK character from the set of AS

Página 163

Interface Related Features3-26 PowerScan® 7000 Linear ImagerRS-232 Interface Features — cont.Retry on ACK NAK TimeoutEnables/disables retry after the

Página 164 - MSI/Plessey

Interface FeaturesProduct Reference Guide 3-27RS-232 Interface Features — cont.ACK NAK Timeout ValueSTARTMODE BARCODEThis item specifies the time the

Página 165 - MSI/Plessey — continued

Interface Related Features3-28 PowerScan® 7000 Linear ImagerRS-232 Interface Features — cont.ACK NAK Retry CountSTARTMODE BARCODEThis feature sets the

Página 166

Interface FeaturesProduct Reference Guide 3-29RS-232 Interface Features — cont.ACK NAK Error HandlingThis item specifies the method the scanner will u

Página 167

Interface Related Features3-30 PowerScan® 7000 Linear ImagerRS-232 Interface Features — cont.Transmission Failure IndicationEnables/disables bad-label

Página 168

Interface FeaturesProduct Reference Guide 3-31IBM-USB Interface FeaturesIBM-USB Device usageThe IBM-USB protocol allows for the scanner to be identifi

Página 169

iv PowerScan® 7000Code 93 Length 1, Length 2 Programming Instructions ...5-69Code 93 Stitching ...

Página 170

Interface Related Features3-32 PowerScan® 7000 Linear ImagerIBMIBM Transmit Labels in Code 39 FormatThis feature enables/disables scanner's abili

Página 171

Interface FeaturesProduct Reference Guide 3-33Wand EmulationSupported SymbologiesThe Wand Emulation interface will transmit bar code data as a wand de

Página 172 - Standard 2 of 5

Interface Related Features3-34 PowerScan® 7000 Linear ImagerWand Emulation — cont.Bar/Space Polarity Low/High — Black will be transmitted as a low vol

Página 173 - Standard 2 of 5 — continued

Interface FeaturesProduct Reference Guide 3-35Wand Emulation — cont.STARTSTATE BARCODEWand Idle State = LowWand Idle State = HighEND

Página 174

Interface Related Features3-36 PowerScan® 7000 Linear ImagerWand Emulation — cont.Signal SpeedThe speed of the transmission can be set. This selects

Página 175

Interface FeaturesProduct Reference Guide 3-37Wand Emulation — cont.Transmit Leading NoiseThe transmission of noise pulses before the bar code may be

Página 176

Interface Related Features3-38 PowerScan® 7000 Linear ImagerSymbology ConversionWand Emulation can convert all bar codes to a single symbology. Choice

Página 177

Interface FeaturesProduct Reference Guide 3-39Symbology Conversion — cont.STARTSTATE BARCODEConvert to C39Convert toC128END

Página 178

Interface Related Features3-40 PowerScan® 7000 Linear ImagerKeyboard Wedge/USB KeyboardAs a keyboard interface, the scanner supports most popular PCs

Página 179 - Disable/Enable PDF 417

Interface FeaturesProduct Reference Guide 3-41Keyboard Wedge/USB Keyboard — cont.STARTSTATE BARCODEFranceGermanyItalyNorwayPortugalSpainSweden

Página 180 - PDF 417 — continued

Product Reference Guide 1-1Chapter 1Getting StartedThe PowerScan® 7000 Linear Imager marks a new performance level for handheld scanners. It delivers

Página 181

Interface Related Features3-42 PowerScan® 7000 Linear ImagerKeyboard Wedge/USB Keyboard — cont.STARTSTATE BARCODESwitzerlandJapan 106 KeyHungaryCzechS

Página 182

Interface FeaturesProduct Reference Guide 3-43Keyboard Wedge/USB Keyboard — cont.STARTSTATE BARCODECroatiaPolandEND

Página 183

Interface Related Features3-44 PowerScan® 7000 Linear ImagerKeyboard Wedge/USB Keyboard — cont.Caps Lock StateSpecifies which format the scanner sends

Página 184 - Symbologies

Interface FeaturesProduct Reference Guide 3-45Keyboard Wedge/USB Keyboard — cont.Keyboard SimulationAll PCs check the keyboard status during the power

Página 185 - Product Specifications

Interface Related Features3-46 PowerScan® 7000 Linear ImagerKeyboard Wedge/USB Keyboard — cont.STARTSTATE BARCODEDisableKeyboardSimulationEnableKeyboa

Página 186 - Electrical Parameters

Interface FeaturesProduct Reference Guide 3-47Keyboard Wedge/USB Keyboard — cont.Wedge Quiet IntervalQuiet Interval is the amount of time to look for

Página 187 - Other Parameters

Interface Related Features3-48 PowerScan® 7000 Linear ImagerKeyboard Wedge/USB Keyboard — cont.Intercharacter DelayNOTEThis feature does not apply to

Página 188 - A-4 PowerScan

Product Reference Guide 4-1Chapter 4Data EditingData Editing OverviewWhen a bar code is scanned, additional information can be sent to the host comput

Página 189 - Cable Pinouts

Data Editing4-2 PowerScan® 7000 Linear ImagerPlease Keep In Mind...• Modifying a message string is not a mandatory requirement. Data editing is sophi

Página 190 - Wand Emulation

Global Prefix/SuffixProduct Reference Guide 4-3Global Prefix/Suffix — continuedExample: Setting a PrefixIn this example, we’ll set a prefix for all sy

Página 191 - 10 Position RJ

Getting Started1-2 PowerScan® 7000 Linear ImagerManual ConventionsThe symbols listed below are used in this manual to notify the reader of key issues

Página 192

Data Editing4-4 PowerScan® 7000 Linear ImagerGlobal Prefix/Suffix — continuedSTARTMODE BARCODESets up to 20 characters each from the set of ASCII char

Página 193 - Alpha-Numeric Pad

AIM IDProduct Reference Guide 4-5AIM IDAIM label identifiers (as opposed to custom characters you select your-self as with label identifiers) can be i

Página 194

Data Editing4-6 PowerScan® 7000 Linear ImagerAIM ID — continuedSTARTSTATE BARCODEDisable AIM IDEnable AIM IDEND

Página 195 - Default Settings

Label IDProduct Reference Guide 4-7Label IDA Label ID is a customizable code of up to two ASCII characters (00-FF), used to identify a bar code (symbo

Página 196 - Interface Default Exceptions

Data Editing4-8 PowerScan® 7000 Linear ImagerLabel ID — continuedSTARTOPTION BARCODELabel IDTransmission: DisableLabel IDPosition: Before Bar Code Dat

Página 197 - RS-232 Wincor/Nixdorf

Label IDProduct Reference Guide 4-9Label ID — continuedSTARTOPTION BARCODESet UPC-Aw/C128 AddonLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE: A

Página 198 - Keyboards

Data Editing4-10 PowerScan® 7000 Linear ImagerLabel ID — continuedSTARTOPTION BARCODESet EAN-8w/P5 AddonLabel IDCharacter(s)DEFAULT SETTING FOR THIS F

Página 199 - Key Mappings

Label IDProduct Reference Guide 4-11Label ID — continuedSTARTOPTION BARCODESet GTINLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE: G (47 hex)Set

Página 200 - E-2 PowerScan

Data Editing4-12 PowerScan® 7000 Linear ImagerLabel ID — continuedSTARTOPTION BARCODESet RSS ExpandedLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEAT

Página 201

Label IDProduct Reference Guide 4-13Label ID — continuedSTARTOPTION BARCODESetCodabarLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE: % (25 hex)S

Página 202 - E-4 PowerScan

Connecting the ScannerProduct Reference Guide 1-3Figure 1. RS-232 Serial ConnectionUSB Connection — Connect the scanner to a USB port on the termi-nal

Página 203

Data Editing4-14 PowerScan® 7000 Linear ImagerCase ConversionThis feature can convert scanned bar code data to either all lower case or all upper case

Página 204 - E-6 PowerScan

Label IDProduct Reference Guide 4-15Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character pai

Página 205

Data Editing4-16 PowerScan® 7000 Linear ImagerCharacter Conversion — continuedSTARTMODE BARCODECharacterConversionDEFAULT SETTING FOR THIS FEATURE:FFF

Página 206 - E-8 PowerScan

Product Reference Guide 5-1Chapter 5SymbologiesThe scanner supports the following symbologies (bar code types). Options for each symbology are include

Página 207 - Host Commands

Symbologies5-2 PowerScan® 7000 Linear ImagerUPC-AThe following options apply to the UPC-A symbology.Disable/Enable UPC-AWhen disabled, the scanner wil

Página 208 - F-2 PowerScan

UPC-AProduct Reference Guide 5-3UPC-A — continuedSTARTSTATE BARCODEDisable UPC-AEnable UPC-ADon’t Send Check DigitSendCheck DigitDon’t Expand to EAN-1

Página 209 - Sample Symbols

Symbologies5-4 PowerScan® 7000 Linear ImagerUPC-A — continuedSTARTSTATE BARCODEDisable Sys-tem Number TransmissionEnable System Number Trans-missionEN

Página 210

UPC-AProduct Reference Guide 5-5UPC-A — continuedUPC-A Minimum ReadsThis feature specifies the minimum number of consecutive times a UPC-A label must

Página 211 - ASCII Chart

Symbologies5-6 PowerScan® 7000 Linear ImagerUPC-A — continuedIn-store Minimum ReadsThis feature specifies the minimum number of consecutive times an i

Página 212

UPC-AProduct Reference Guide 5-7UPC-A — continuedSTARTSTATE BARCODEThis item is used to set the timer value when optional add-ons are enabled. The sel

Comentários a estes Manuais

Sem comentários