Systems Manual
57
Wait Time For
Scanner Power
Shutdown
To conserve battery life, the handheld scanner can be automatically
shut down when it has not been in use for a given period. A trigger
pull or other stimulus will then be required to reactivate the scanner.
The idle duration determines how long the scanner stays on/active
after each use. Range for this feature is a setting of 1 to 120 seconds in
one-second increments. A setting of one second is recommended.
Feature is specific to scanner ONLY
NOTE
Selecting higher values for this feature will effect
the length of battery life.
SET -------------------------------------------
Set Wait Time for Scanner
Power Shutdown ---------
Scan three digits representing the desired delay using the Num-
ber Pad in Appendix B. Be sure the number is padded with lead-
ing zeros (example: 001 = 1 second, 025 = 25 seconds, 100 = 100
seconds, etc.), then scan the END bar code.
END ------------------------------------------