PSC Scanners Especificações Página 376

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 440
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 375
6-268 Magellan
®
8100/8200 Scanner
Standard 2 of 5 Fixed Length 2
This feature specifies Standard 2 of 5 second fixed length.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET STANDARD 2 OF 5 FIXED LENGTH 2
below. You’ll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that rep-
resent the desired fixed label length. The selectable range for this
option is 1 to 50. Pad all single digit numbers with a leading zero to
yield a two-digit entry (01-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET STANDARD 2 OF 5 FIXED LENGTH 2
NOTE
This applies when Standard 2 of 5 Length Control is set to fixed-
length decoding.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
Vista de página 375
1 2 ... 371 372 373 374 375 376 377 378 379 380 381 ... 439 440

Comentários a estes Manuais

Sem comentários