Product Reference Guide 7-53
EAS Deactivation Duration — Manual
Specifies the amount of time EAS deactivation is operative upon pushing
the Manual EAS Deactivation Push Button
NOTE
This setting pertains only to units configured for EAS Coupled Mode. Refer-
ence the “EAS Mode ” description for more information about Coupled and
Decoupled EAS operation. Also reference “EAS Retry Count .”
.
To set the EAS Deactivation Duration — Manual:
1. Scan the SWITCH barcode.
2. Scan the barcode,
SET EAS DEACTIVATION DURATION — MANUAL
below. You’ll need to cover any unused barcodes on this and the fac-
ing page to ensure that the scanner reads only the barcode you
intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired duration. The selectable range is 1-255, which is
the duration
in 50-millisecond increments. Pad all single and double
digit numbers with leading zeroes to yield a 3-digit entry (001-255).
Examples:
001 = 50ms
008 = 400ms
050 = 2,500ms (2.5 seconds)
The scanner will automatically exit P
rogramming Mode when the appro-
priate amount of digits have been scanned