Vista de página 361
7-224 Magellan
TM
8500Xt Scanner
Code 128 Length 1
If Code 128 Length Control is set to Fixed-Length decoding, this feature
specifies Code 128 first fixed length. If Code 128 Length Control is set to
Variable-Length decoding, this feature specifies the minmum label length.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET CODE 128 LENGTH 1 below. You’ll
need to cover any unused barcodes on this and the facing page to
en
sure that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that
represent the desired label length. The selectable range for this
option is 01 to 80.
Pad all single digit numbers with a leading
zero to yield a two-digit entry (01-80).
4. Complete the programming seque
nce by scanning the SWITCH
barcode.